Fire Alarm System Main Distributor In Iraq
Up to 120 addresses on one loop.
The loop supports class A and Class B types.
An easy to read, 4.3"color screen LCD with a resolution of 480×272.
Zone indicators for 16 zones gives a quick indication of the location of an alarm.
Record capacity of 1000 historical events for each of historical fire, historical fault and historical operation.
An independently programmable conventional sounder circuit output.
Integral power supply and battery.
Flexible and intuitive cause and effect programming on front panel.
Zone test, point test and module start/stop testing facilitate the commissioning.
U-disk interface makes the load and save of configuration or historical data convenient for system commissioning and maintenance.
Hierarchy management with three access levels.
Anti-tamper protection by a key lock.
CAN bus for interconnection of up to 20 FACPs.
EN54-2&EN54-4 certified by LPCB and Applus.
7.0 inch color touch-sensitive screen LCD, resolution of 800×480.
324 addresses for 1 loop,max 8 loops.
A maximum of 5000 fire protection zones are supported.More user-friendly Night Mode Time Range Settings.
Networkable: CAN bus for interconnection of up to 60 FACPs and Ethernet for up to 254 FACPs.
Fire alarm, fault, C&E and operation, each category can store up to 10000 records.
EN54-2&EN54-4 certified by LPCB and Applus.
7.0 inch color touch-sensitive screen LCD, resolution of 800×480.
324 addresses for 1 loop,max 4 loops.
A maximum of 5000 fire protection zones are supported.More user-friendly Night Mode Time Range Settings.
Networkable: CAN bus for interconnection of up to 60 FACPs and Ethernet for up to 254 FACPs.
Fire alarm, fault, C&E and operation, each category can store up to 10000 records
LPCB & CPR approval
It supports soft addressing and rewriting the address via coder in situ
Within a single-chip microcomputer, it can process the sampling data in real-time, save the latest 144 historical data and realize a curve tracing for the field situation
LPCB and CPR approval
It supports soft addressing and rewriting the address via coder in situ.
Within a single-chip microcomputer, it can collect real-time data and then process it to realize a curve tracing for the field situation.
The low profile design of the Optical/Heat Multisensor detector Detector is sleek and evolutionary, with a 360° LED indicator which illuminates red when in alarm.
Non-polarity, two-bus connection that ensures convenient installation and maintenance.
It can realize electronic coding and rewrite the address via coder in site.
Within a single-chip MCU, it can realize real-time data acquisition and processing, realize a curve tracing for the field situation.
It has a temperature, humidity and dust accumulation drift compensation function and a sensor fault detection function (fault reporting to fire alarm control panel).
A sophisticated dynamic algorithm, providing transient rejection and compensation for drift whilst maintaining accurate sensitivity.
LPCB and CPR approval.
Semi-flush or surface mount.
Lever reusable (non-glass break).
LED indicator.
Meet both EN54-3 and EN54-23.
Designed with an upper cover and a lower cover and installed on an independent base, it can be installed,debugged and maintained conveniently.
Suitable for wall and ceiling mount application.
Providing 16 tones.
Highly efficient LED technology and specially designed lens.
Light output synchronization.
Up to 16 Zones
Walk test function
Disablement facility for zones & sounders
Space for up to 7Ah batteries
Sounder delay option
4 sounder circuits
Two sounder circuits can be configured as Aux 24V supplies
Supports Repeater communication interface
Meets all requirements of EN 54-2&4
Designed with an upper cover and a lower cover, it can be installed, debugged and maintained conveniently.
Real-time monitoring to accurately determine ambient temperature conditions in protected areas.
Non-addressable, non-polarity, two-bus connection that ensures convenient installation and maintenance.
Designed with an upper cover and a lower cover, it can be installed, debugged and maintained conveniently. Real-time monitoring to accurately determine ambient temperature conditions in protected areas.
Non-addressable, non-polarity, two-bus connection that ensures convenient installation and maintenance.
Designed with an upper cover and a lower cover, it can be installed, debugged and maintained conveniently.
Multiple can be used in parallel, and the terminal load must be connected at the end.
The pressing sheet on the manual fire alarm call point will not get crushed after it is pressed, but can be reset by a special tool, so it can be used repeatedly.
Choice of up to tone modes.
Adopting independent base, it is simple and convenient for installation, commissioning and maintenance.
The light display adopts multiple ultra-high brightness light-emitting diodes as the light source, with eye-catching display,long life and low power consumption.
Tamper-evident function is possible.